CFYRK - FUJI II LC POWDER

  • MSDS: CFYRK
  • Manufacturer: GC AMERICA INC
  • Product Name: FUJI II LC POWDER
  • National Stock Number: 6520-01-371-8368
Product Identification

Product ID:FUJI II LC POWDER
MSDS Date:10/01/1995
FSC:6520
NIIN:01-371-8368
Kit Part:Y
MSDS Number: CFYRK

Responsible Party
GC AMERICA INC
3737 WEST 127TH STREET
CHICAGO, IL 60658
US

Emergency Phone: 800-424-9300(CHEMTREC)/708-597-0900

Info Phone: 708-597-0900

Preparer: T. JORITZ

Cage: GO295

Contractor
GC AMERICA INC
72076 CHICAGO, IL 60658-2076 US

Telephone: 708-597-0900

Cage: GO295

Ingredients

ALUMINO-SILICATE GLASS

Fraction By Weight: 100%

Hazards

LD50 LC50 Mixture:NONE SPECIFIED BY MANUFACTURER.
Routes of Entry: Inhalation:YES Skin:NO Ingestion:NO
Reports of Carcinogenicity:NTP:NO IARC:YES OSHA:NO
Health Hazards Acute and Chronic:CONTAINS SILICA GLASS WHICH IS
CONSIDERED A HAZARD BY INHAL.DUSTS OF SILICA GLASS IS ALSO KNOWN
CAUSE OF SILICOSIS, A NON-CANCEROUS LUNG DISEASE.
Explanation of Carcinogenicity:PER MSDS:IARC HAS CLASSIFIED SILICA
GLASS AS PROBABLE CARC FOR HUMANS.
Effects of Overexposure:IRRITATION AND SORENESS IN THROAT AND NOSE.
Medical Cond Aggravated by Exposure:MAY AGGRAVATE PRE-EXISTING UPPER
RESPIRATORY AND LUNG DISEASE.

First Aid

First Aid:INGEST:INGESTION MAY REQUIRE MEDICAL ASSISTANCE.SKIN:WASH
W/SOAP/WATER.EYE:FLUSH W/LARGE QUANTITIES OF WATER.IF IRRIT DEVELPS
OR PERSISTS SEEK MED ATTN.INHAL:REMOVE TO FRESH AIR,DRINK WATER TO
CLEAR T HROAT ADN BLOW NOSE TO EVACUATE DUST.

Fire Fighting

Flash Point:NOT FLAMMABLE
Autoignition Temp:Autoignition Temp Text:NP
Lower Limits:NA
Upper Limits:NA
Extinguishing Media:MATERIAL IS NOT COMBUSTIBLE.USE EXTINGUISHING MEDIA
APPROPRIATE TO SURROUNDING AREA.

Accidental Release

Spill Release Procedures:AVOID GENERATING DUST WHILE SWEEPING.IF AN
EXCESSIVE AMT OF DUST IS GENERATED USE A FILTER EQUIPPED VACUUM AND
MSHA/NIOSH APPROVED MASK.
Neutralizing Agent:NONE SPECIFIED BY MANUFACTURER.

Handling

Handling and Storage Precautions:STORE IN NORMAL ROOM TEMPERATURES AND
HUMIDITY.
Other Precautions:PRODUCT USE:LIGHT-CURED GLASS IONOMER FOR DENTAL
CAVITY PREPARATIONS.(POWDER COMPONENT).SHELF LIFE INFO:SHELF LIFE
OF POW/LIQ IS 36MON FRM DATA OF MFG & FOR CAPSULES IS 24MONS.DATE
DETERMINED BY BATCH #.CAPSULES USE SAME BATCH(SUPPLEMTN)

Exposure Controls

Respiratory Protection:MINIMIZE EXPOSURE TO DUST IN ACCORDANCE WITH
GOOD HYGIENE PRACTICE.IF NEEDED USE MSHA/NIOSH APPROVED RESPIRATOR
FOR DUSTS/MISTS/FUMES.
Ventilation:LOCAL EXHAUST/MECHANICAL:YES.
Protective Gloves:DISPO VINYL GLOVES RECOMMENDED
Eye Protection:SAFETY GLASSES
Other Protective Equipment:EYEWASH STATION.
Work Hygienic Practices:FOLLOW SAFE HYGIENE PRACTICES.
Supplemental Safety and Health
OTHER PRECAUT:NUMBER FORMAT AS EXAMPLE BUT ALSO HAVE LETTER @END TO
INDICATE PARTICULAR LOT W/IN DAY.WHILE MANY BATCHES OF MATL WILL
CONTINUE TO PERFOMR AS CLAIMED BEYOND RECOMMENDED SHELF LIFE THIS C
ANNOT BE GUARANTEED.

Chemical Properties

HCC:N1
Boiling Pt:B.P. Text:NE
Melt/Freeze Pt:M.P/F.P Text:>2462F,>135
Decomp Temp:Decomp Text:NP
Vapor Pres:NE
Vapor Density:NE
Spec Gravity:2.56
pH:NP
Viscosity:NP
Evaporation Rate & Reference:NE
Solubility in Water:INSOLUBLE
Appearance and Odor:VERY FINE WHITE POWDER,CORE MATERIAL IS LIGHT BLUE
IN COLOR
Percent Volatiles by Volume:NP
Corrosion Rate:NP

Stability

Stability Indicator/Materials to Avoid:YES
CONTAINS SILICA GLASS.AVOID CONTACT W/HYDROFLUORIC ACID.COTNACT W/ACIDS
LIBERATES HYDROGEN FLUORIDE GAS-TOXIC/CORROSIVE.
Stability Condition to Avoid:AVOID HGIH TEMPERATUES AND HUMIDITY.
Hazardous Decomposition Products:@ELEVA TEMPS VAR FLUORIDE CMPDS WILL
BE LIBERATED,INCLUDE TOXIC HYDROGEN FLUOIRIDE & SODIUM POTASSIUM
FLUORIDE;CO,CO2.

Disposal

Waste Disposal Methods:IN ACCORDANCE WITH LOCAL, STATE AND FEDERAL
REGULATIONS.

Disclaimer (provided with this information by the compiling agencies):
This information is formulated for use by elements of the Department
of Defense. The United States of America in no manner whatsoever,
expressly or implied, warrants this information to be accurate and
disclaims all liability for its use. Any person utilizing this
document should seek competent professional advice to verify and
assume responsibility for the suitability of this information to their
particular situation.